Tech Support for LoRaWAN Gateway (Indoor)

Find setup guides, datasheets, and expert support options below.

LoRaWAN Gateway (Indoor)

Downloads & Guides

Access the latest firmware, manuals, and software tools.

Integration Support

Need assistance configuring protocols or connecting to SCADA?

Book Remote Session

Technical Specifications

LoRaWAN Communication Protocol Support: LoRaWAN LoRa Classes: Class A, Class C Operating Frequency Bands: EU433, CN470–510, EU863–870, US902–928, AU915–928, AS923, KR920–923 Receiver Sensitivity: -142 dBm @ LoRa Urban Communication Range: Up to 3.5 km Upstream Channels: 8 channels Downstream Channels: 1 channel Data Rate: Adaptive Data Rate (ADR)
Network & Interfaces Ethernet Ports: 1 × WAN/LAN, 1 × LAN (RJ45) Wireless Interfaces: Wi-Fi 802.11 b/g/n Serial Interfaces: RS232 (RS485/RS422 optional) Server Connectivity: Ethernet or 3G/4G uplink
Hardware & System Processor: Industrial-grade 32-bit CPU Operating System: Embedded real-time OS System Protection: Watchdog timer, over-voltage protection Antenna Interfaces: LoRa, Wi-Fi, Cellular (SMA connectors)
Power & Consumption Input Voltage: DC 9–36V (12V/1.5A standard) Standby Current: ≤145 mA @ 12V Transmit Current: ≤450 mA @ 12V Receive Current: ≤390 mA @ 12V
Mechanical & Environmental Enclosure Material: Metal housing Protection Rating: IP30 Dimensions: 157 × 97 × 25 mm Weight: 510 g Operating Temperature: -35°C to +75°C Storage Temperature: -40°C to +85°C Humidity: 95% non-condensing Certifications: CE

Frequently Asked Questions

Find answers to the most common questions about this product.

It is used to collect data from LoRaWAN sensors and transmit it securely to cloud servers for monitoring, analytics, and automation in industrial and enterprise IoT applications.

Yes, it is designed specifically for indoor use in factories, smart buildings, control rooms, and enterprise facilities requiring stable and long-range LoRaWAN communication.

The gateway can be wall-mounted or placed on a flat surface. Installation accessories are provided, and antenna placement should ensure minimal signal obstruction.

It operates on DC power with a wide input range of 9–36V, with 12V/1.5A recommended for optimal performance.

Yes, it forwards data to cloud platforms via Ethernet or cellular backhaul and is compatible with standard LoRaWAN network servers.

The gateway supports multiple LoRaWAN end devices using 8 upstream channels, making it suitable for medium to large indoor deployments.

No, Wi-Fi is optional and mainly used for management and configuration. Primary data transmission is via Ethernet or cellular networks.

Still have questions? Contact our support team

Still need assistance?

Our engineering team is ready to help.